Neutrons carry no charge, so no detector sees them directly. Every neutron detector first converts the neutron into a charged particle, through capture in helium-3, boron-10 or lithium-6, a recoiling proton, fission, or activation, and then detects that. The conversion you choose decides the detector's efficiency, energy range, gamma sensitivity and cost.
This guide compares the main methods, active and passive: helium-3 and BF3 tubes, boron-lined counters, lithium-6 and organic scintillators, fission chambers, Bonner spheres, activation foils, bubble detectors, albedo TLDs and CR-39 track detectors.
By Noah D'Amico, PhD, BlankSlate Innovation · Last reviewed 18 November 2026
Starting point
How Do Neutron Detectors Convert a Neutron?
Six conversion mechanisms cover almost every neutron detector in use. Capture reactions favor slow neutrons, which is why detectors for fast neutrons are often wrapped in a hydrogen-rich moderator to slow them down first.
| Conversion | Reaction | Thermal cross-section | Best for |
|---|---|---|---|
| Helium-3 capture | He-3(n,p)T, releasing 0.764 MeV | About 5,330 barns | Thermal neutrons; fast neutrons after moderation |
| Boron-10 capture | B-10(n,alpha)Li-7, releasing 2.31 MeV in 94% of captures | About 3,840 barns | Thermal and epithermal neutrons |
| Lithium-6 capture | Li-6(n,t)alpha, releasing 4.78 MeV | About 940 barns | Thermal neutrons, in scintillators and TLDs |
| Proton recoil | Elastic scattering on hydrogen | Not a capture reaction | Fast neutrons, roughly 100 keV and up |
| Fission | U-235(n,f), releasing about 200 MeV | About 585 barns | Very high flux and harsh environments |
| Activation | A capture or threshold reaction that leaves a radioactive product | Depends on the foil | Time-integrated fluence in any field |
Live readout
Active Neutron Detectors Compared
Active detectors produce an electrical pulse for each detected neutron, so they give count rate and, in some cases, timing and energy.
| Method | How it works | Strengths | Limits | Typical use |
|---|---|---|---|---|
| Helium-3 proportional counter | He-3 gas captures thermal neutrons; a moderator slows fast ones first | Highest thermal efficiency per volume. Excellent gamma rejection. Stable and long-lived | Helium-3 is scarce and expensive. Needs high voltage. Moderated counting loses energy information | Safeguards, portal monitors, neutron scattering, well logging |
| BF3 proportional counter | Boron trifluoride gas, enriched in boron-10 | Cheaper than helium-3. Good gamma rejection | BF3 is toxic and corrosive. Lower efficiency per tube. Higher operating voltage | Area monitors, older reactor and survey instruments |
| Boron-lined counter | A thin solid boron-10 coating on tube or straw walls | Non-toxic and uses no helium-3. Scales to large areas | Lower efficiency per tube, so more tubes are needed | Helium-3 replacement in portal monitors |
| Lithium-6 scintillators (Li glass, LiF/ZnS, CLYC) | Capture in lithium-6 produces a flash of light | Compact and fast. CLYC measures gammas and neutrons in one crystal | Li glass is gamma-sensitive. LiF/ZnS screens are opaque, which limits thickness. CLYC is costly | Handheld instruments, neutron imaging, scattering instruments |
| Organic scintillators (liquid, plastic, stilbene) | Fast neutrons scatter off hydrogen, and the recoil protons make light | Nanosecond timing. Energy spectra by time of flight or unfolding. Pulse-shape discrimination separates neutrons from gammas | Gamma-sensitive without pulse-shape discrimination. Poor for thermal neutrons. Some liquids are flammable or toxic | Fast-neutron spectroscopy, time of flight, fusion and accelerator work |
| Fission chamber | Neutrons fission a thin uranium coating | Very wide dynamic range. Radiation-hard and gamma-insensitive | Low efficiency. Contains fissile material, with the licensing that follows | Reactor power monitoring, tokamak yield monitors |
| Bonner sphere spectrometer | A thermal detector placed inside moderating spheres of several sizes | Covers thermal to hundreds of MeV with one system | Poor energy resolution. The spectrum must be unfolded. Slow, with many measurements | Workplace and accelerator field characterization |
Read afterwards
Passive Neutron Detectors Compared
Passive detectors have no active electronics during the exposure. They cannot saturate electronically, pile up or pick up noise, and they give only one number per exposure: total flux.
| Method | How it works | Strengths | Limits | Typical use |
|---|---|---|---|---|
| Activation foils (gold, indium and others) | Neutrons make the foil radioactive, and a gamma counter reads it afterwards | Absolute fluence. No electronics during exposure. Unaffected by gammas, EMP or pulse rate | Time-integrated. Needs a gamma spectrometer and prompt counting. Each foil covers one energy region | Reactor and accelerator flux mapping, pulsed sources, calibrations |
| Bubble detectors | Neutrons trigger visible bubbles in a superheated gel | Read by eye in minutes. Gamma-insensitive. Reusable for a limited number of cycles | Temperature-dependent. Limited dynamic range and shelf life | Personal and area dosimetry, quick surveys |
| Albedo TLD dosimeters | Lithium-6 and lithium-7 thermoluminescent chips read the neutrons scattered back by the body | Small, reusable and cheap per reading. Established for personnel dosimetry | Strongly energy-dependent. Needs the wearer's body as moderator, and site-specific calibration | Routine personnel neutron dosimetry |
| CR-39 track detectors | Recoil protons leave etchable tracks; a boron coating adds thermal response | Insensitive to gammas, X-rays and EMP. Permanent record. Small and cheap enough to deploy by the hundred | Low efficiency: roughly 1 in 10,000 to 1 in 1,000,000 for bare plastic. Time-integrated. Needs etching and track counting | Personnel dosimetry, pulsed and mixed fields, fusion experiments, long unattended exposures |
Decision table
Which Neutron Detector Should You Use?
| Situation | Good choices | Why |
|---|---|---|
| Counting thermal neutrons at a steady rate | Helium-3, boron-lined or BF3 counters | High capture cross-section and clean gamma rejection |
| Fast-neutron timing or spectra | Organic scintillators | Nanosecond response and pulse-shape discrimination |
| Intense pulses, strong gamma or EMP | Activation foils, CR-39, bubble detectors | Passive detectors cannot pile up or pick up noise |
| Many positions on a small budget | CR-39, activation foils | Low cost per position and no cabling |
| Long unattended exposures | CR-39 | No power, and the record is permanent |
| Personnel dosimetry | Albedo TLDs, CR-39, bubble detectors | Small, wearable and passive |
| Unknown spectrum over a wide energy range | Bonner spheres | One system covers thermal to very high energies |
| Extreme flux and radiation damage | Fission chambers | Wide dynamic range and radiation hardness |
Supply
Why Is Helium-3 Scarce?
Helium-3 has been the reference neutron-detector gas for decades. Almost all commercial helium-3 comes from the radioactive decay of tritium held in national stockpiles, so supply is set by how much tritium exists and not by demand. After 2001, large numbers of radiation portal monitors were deployed, demand outran supply, and by 2008 to 2009 the shortage was acknowledged and helium-3 was being allocated. That is what drove the boron-lined, BF3 and lithium-6 alternatives in the tables above.
A second possible source is natural gas, since some helium-bearing gas contains measurable helium-3. Finding it takes a mass spectrometer that can separate helium-3 from HD at mass 3. See helium-3 testing for natural gas.
Available here
One of These Methods Is Made in Lubbock, Texas
BlankSlate Innovation manufactures CR-39 track detectors for passive neutron detection: bare for fast neutrons, and boron-nitride coated for thermal and epithermal neutrons. Standard CR-39 is $2/cm2 and boron-coated is $5/cm2.
We measured a bare-CR-39 efficiency of about 4 × 10-5 at 14 MeV, and the coating results are peer-reviewed (reference 4). CR-39 will not replace a helium-3 tube for live counting. It is the right tool when the field is pulsed, mixed or unpowered.
Order CR-39 · SSNTD materials guide · Fusion diagnostics methods compared · Talk to our team
Questions people ask
Neutron Detection FAQ
What is the best neutron detector?
There is no single best neutron detector. Helium-3 proportional counters give the highest thermal-neutron efficiency with excellent gamma rejection. Organic scintillators are best for fast-neutron timing and spectra. Passive detectors such as activation foils, bubble detectors and CR-39 are best in pulsed, high-gamma or unpowered settings. The right choice depends on neutron energy, rate, gamma background, and whether real-time readout is needed.
Why is helium-3 used in neutron detectors?
Helium-3 captures thermal neutrons with a very large cross-section, about 5,330 barns, and releases a proton and a triton that are easy to detect in a gas proportional counter. The gas is non-toxic, the tubes are stable for decades, and gamma rays produce much smaller pulses, so they are easy to reject. Its drawback is scarcity: helium-3 is a by-product of tritium decay.
What can replace helium-3 for neutron detection?
The main alternatives are boron-lined proportional counters, boron trifluoride tubes, and lithium-6 scintillators such as LiF/ZnS screens, lithium glass and CLYC crystals. Each has lower efficiency per unit volume than pressurized helium-3, so replacements usually use more detector area. For time-integrated measurements, passive methods such as activation foils and boron-coated CR-39 need no helium-3 at all.
How do you detect neutrons in a strong gamma or pulsed radiation field?
Use a passive detector. Activation foils, bubble detectors and CR-39 track detectors do not respond to gamma rays or electromagnetic pulse and cannot pile up, because they have no electronics during the exposure. They give a time-integrated result. If timing is needed, a shielded organic scintillator with pulse-shape discrimination is added at a distance.
Can CR-39 detect neutrons?
Yes, indirectly. Fast neutrons knock protons out of the plastic, and each recoil proton leaves an etchable track. Bare CR-39 detects roughly one neutron in 10,000 to one in 1,000,000, depending on energy. A boron converter coating adds thermal and epithermal sensitivity through the boron-10 capture reaction. CR-39 is time-integrated and must be etched and read after exposure.
Sources
References and Further Reading
- G. F. Knoll, Radiation Detection and Measurement, 4th ed., Wiley, 2010.
- R. T. Kouzes et al., "Neutron detection alternatives to 3He for national security applications," Nuclear Instruments and Methods in Physics Research A 623, 1035 (2010). doi.org/10.1016/j.nima.2010.08.021
- D. A. Shea and D. Morgan, "The Helium-3 Shortage: Supply, Demand, and Options for Congress," Congressional Research Service Report R41419, 2010.
- N. D'Amico et al., "Boron nitride coatings for the enhanced detection of neutrons in CR-39," Nuclear Engineering and Technology 58, 104027 (2026). doi.org/10.1016/j.net.2025.104027
- J. A. Frenje et al., "Absolute measurements of neutron yields from DD and DT implosions at the OMEGA laser facility using CR-39 track detectors," Review of Scientific Instruments 73, 2597 (2002). doi.org/10.1063/1.1487889